ECUDAP [Environmental Quality Controll]
HOME
WHO ARE WE?
PRODUCTS
SOFTWARE
DOWNLOADS
CONTACT US
  PdeAUDIO [Proceso Digital de Audio]
Management Tools

Dynamic noise maps
IR Enter

Environmental Control System
IR Enter

Activities Automatic Inspection System
IR Enter

Proyectos

23-June-2005
Experts propose social working instead of fines as a penalty for these who drink alcohol outside on the street.

23-June-2005
BENALMÁDENA: Izquierda Unida denounces noise pollution caused by Palmasol hotel.

MORE

News and Events

23-June-2005
Experts propose social working instead of fines as a penalty for these who drink alcohol outside on the street.

23-June-2005
BENALMÁDENA: Izquierda Unida denounces noise pollution caused by Palmasol hotel.

MORE

Environmental Quality Control

NOISE POLLUTION
Noise pollution is nowadays considered to be one of the biggest environmental problems, for it not only deteriorates the environment but it also causes physical and psychological disturbances to people who are exposed to certain noise levels.

MORE

SDR-500R

 

A system to measure outdoor permanent environmental noise which can be part of Proceso Digital de Audio’s SSMmR.

SDR-500R device image

ECUDAP SDR-500R

General characteristics

Permanent outside environmental noise measurement system with the possibility of incorporation to the SSMmR of Proceso Digital de Audio.

System components

  • RION NL-31 sonometer, type 1 according to UNE 60651/60804 norm [approval of the model in Spain number I-128-16-02021]. It conforms to the new IEC 61672-1 norm, class 1 or any other sonometer that incorporates an RS-232 port.
  • Weatherproof rack (see below).
  • Software set-up and management system (see below).

Measurement set-up from PC

  • Measurement intervals: 10secs, 1,5,10,15 and 30mins, 1,8 and 24hrs.
  • Measurement parameters: Leq, Lmax, Lmin and Ln (5 values).

Data sending to PC receiver via SMS of GMS, GPRS Ethernet or WI-FI.

System operation

The use of a network of several SDR-500R measurement points is quite easy. After placing the stations in the different control points, the kina of measurement that is going to be made is configured from the control PC through the adaptative device.

Once the period of measurement is over, the stations send data through SMS via GSM or GPRS.  

The received messages are stored in a working directory as files. These received messages can be integrated in an SSMmR network.

The messages are processed, after which they are stored in the data base which is organized by positions, so that all stored data are associated to the device that sent them and its position.

Support software

The software associated to the SDR-500R system includes two programmes:

ECURION: Device set up software, which offers the possibility of configuring the measures made with the sonometer.

GestionSDR: Management of the data software that includes:

Data reception (sms). The messenger module remainsn in the PC receiver, which obtains all the data from the stations connected to the network. At each measurement point, one or several stations can be placed, which can be active or inactive. Once they have been processed, all the data is stored permanently, corresponding to its position.

Message processing module and permanent storage of the data in bases connected to the measuring points. The inserted data corresponds to the positions of the active equipment. Once processed, the data is stored permanently according to its position.

Data exportation for management by spreadsheet.

GestionSDRnet: Software of reception, processing and presentation of the data on the Internet (SSMmR).

 

Technical Features of the SDR-500R Sonometer- Integrator RION NL-31

Sonometer Integrator. It conforms to the UNE 60651/60804 type 1 normative and the new normative IEC 61672-1, class 1.

Frequency weighting A,C or FLAT.

Time weighting: fast and slow.

Measurement range: Leq. 23-138 dB(A); Peak 141 dB(C); Dynamic Range: 100 dB.

Measurement intervals: 10secs, 1, 5, 10, 15, 30 mins., 1, 8, 24 hrs.

Outlet for comparator device.

Acoustic Features of the SDR-500R

Measurement Margin: 42-105 dB(A).

Measurement type: level equivalent to 60" Leq. 60".(Leq 60")

Type II measurement accuracy according to the IEC 651 (UNE-EN 60651).

Protection level of the Anti-wind system of the microphone IP45.

Measurement recorder programmable according to set-up.

Sending of information: every 84 samples saved.

Storage of information in the internal recorder: 2000 samples.

Waterproof rack

Weatherproof equipment with IP 66 CEI-529 protection level.

Communications module for sending data in SMS of GSM format.

A/C supply and reserve battery (24hrs).

Microphone protection system WS-03-S01.

Data Management System

GESTION SDR. Management software package. Includes: Data reception module, message processing module, module for storage and export of data to MS EXCEL.

Other equipment which can be integrated in the SDR-500R

Any measuring equipment can be integrated: sonometer, spectrum analyser and/or vibration recorder which has the RS-232 port.

Metereological instruments for weather parameters measurement.

Español - Français - Deutsch

® EcuDap is a registered trademark by PD de Audio, S.L.
PD de AUDIO. C/ Avila 23 Bajo. 09001 BURGOS SPAIN. Telephone: +34 947 20 70 41 - Fax: +34 947 20 97 74 - Email: pddaudio@ecudap.com
Diseño web: IMAGOTIPO.com