ECUDAP [Environmental Quality Controll]
HOME
WHO ARE WE?
PRODUCTS
SOFTWARE
DOWNLOADS
CONTACT US
  PdeAUDIO [Proceso Digital de Audio]
Management Tools

Dynamic noise maps
IR Enter

Environmental Control System
IR Enter

Activities Automatic Inspection System
IR Enter

Projects
Login:
Password:
 
   
More projects:
IR Proyecto GEDEON
IR Proyecto JERICÓ
IR Ayto. de León
IR Ayto. de Miranda de Ebro
IR Ayto. de Huelva
IR Ayto. de Errentería
News and Events

23-June-2005
Experts propose social working instead of fines as a penalty for these who drink alcohol outside on the street.

23-June-2005
BENALMÁDENA: Izquierda Unida denounces noise pollution caused by Palmasol hotel.

MORE

Environmental Quality

NOISE POLLUTION
Noise pollution is nowadays considered to be one of the biggest environmental problems, for it not only deteriorates the environment but it also causes physical and psychological disturbances to people who are exposed to certain noise levels.

MORE

SDR-120

Sound level recorder

An SDR-120 device image

ECUDAP SDR-120

Control SDR-120

  • Sound level recorder for noise control.

  • Record sonographic parameters LAeq60".

  • Record all incidents: disconnection ofelectrical network,handling.

  • Adjustable to any type of norm.

  • Internal system of calibration.

  • Storage of data.

  • Configuration and obtaining of data thanksto our software.

Characteristics of an EQD-50 SR / EQD-50 SRE device

INPUTS / OUTPUTS

5 Inputs of sensors for relays (0-5V) TTL

Technology

Output for connexion RS-232

Centronics 14

Capacity to send SMS (GSM).

Adapted to Monitoring systems of PdAudio

SSMmR

MICROPHONE SENSOR

Microphonic capsule of condenser with the

characteristics of the type 2.

Measurement range

50 - 110 dBA

Frequencies range

20 - 20KHz

Includes an 8m microphone

CALIBRATION

Auto-calibration for each session

DIMENSIONS ET WEIGHT

250 x 85 x 55 mm.

0,5 Kg.

ALIMENTATION

220V 50 - 60 Hz

MAXIMUM CONSUPTION

25 W

STORAGE CAPACITY

Takes the data in a continuous way in Leq,

as from one minute.

Further its configuration:

Sonographe: 255 sessions

Recorder: 4000 recordings

Functions of an SDR-120 device

The SDR-120 sound level recorder has the same characteristics than our SDR-100 device. The SDR-120 has a visual display. This display represents the sound levels pressure of the premise where it is installed, in dB(A), measured further the interval of time chose by the fitter, between one and sixty seconds, presented as Leq 60" in dB(A).

One of the objectives of the sound level recorder is to determine the periods of activity of the source of noise, thanks to the system of sensors. Another characteristic of the device is its inviolability. We lay out a monitoring system thanks to the sensor (microphone) which makes possible to detect possible handling. Inside the sensor, you have the Speaker/Amplifier/Converter D/A chain which has to detect the no-handling of these elements. Thus, a noise test (pink noise) is emitted. The both sensitivity/effectiveness of the period must remain constant throughout the sessions.

The device can be programmed as a sonographe or as a recorder, like our SDR-100 device. The SDR-120 and our Sound Ambience Supervisor devices can be integrated in the "Environmental Noise Monitoring System", defined by Pd de Audio, thanks to sending the data of the noisy sessions to the management system, using the GSM network, by SMS.

Our Sound Ambience Supervisor (SAS) is intended for the market of the formation and social awakening concerning the problem of the noise.

Agitation is currently a social organizer and the fruit of productive situations, but we are not conscious of the noise levels produced by this agitation. The installation of a device in rooms and recreation zones of schools, on working places, basically in areas where, by nature, the tranquility must reign and where the obtained noise evels are relatively important due to the producers. So, the installation of devices which indicate the ambience type existant in a room such as " Normal Ambience ", " Noisy Ambience " and " Very Noisy Ambience " seems to be most adequate that the indication of the noise level which can be regarded as a technical data for the majority of the population. Thus, the noise level and the ambience type in a local are put in adequacy for each type of premise, knowing that the qualification of "noisy" depends more about the use of a local than about the sound level pressure existing in this one.

These devices are mainly intended for the schools (room and recreation zones), Hospitals attempt rooms (urgencies), working places... etc.

The SDR-120 and the SAS devices continuously take a sample of Leq 60", in a periodic way. This period has to be determined during the SDR-100 device programming. Thus, the inspection will give us the 3000 latest recorded samples, divided in sessions determined by the activity of the source.


sas

The installation and modification of the parameters are made with our own software : GestionSDR. It is protected with various electronic keys:

> Program password > Apparatus password > Print of the program.

For a commodity inspection, you can read the data thanks to a laptop. This one can read and transfer them to a PC. This last one thanks to the Inspection program (our software GestionSDR), treats the data and works out an activity report of the device.

 

Español - Français - Deutsch

® EcuDap is a registered trademark by PD de Audio, S.L.
PD de AUDIO. C/ Avila 23 Bajo. 09001 BURGOS SPAIN. Telephone: +34 947 20 70 41 - Fax: +34 947 20 97 74 - Email: pddaudio@ecudap.com
Diseño web: IMAGOTIPO.com