ECUDAP [Environmental Quality Control]
HOME
WHO ARE WE?
PRODUCTS
SOFTWARE
DOWNLOADS
CONTACT US
  PdeAUDIO [Proceso Digital de Audio]
Management Tools
Proyectos

Dynamic noise maps
IR Enter

Environmental Control System
IR Enter

Activities Automatic Inspection System
IR Enter


Projects
Proyectos

Insert your password to have access to the projects:

Login:
Password:
 
   
More projects:
IR Proyecto GEDEON
IR Proyecto JERICÓ
IR Ayto. de León
IR Ayto. de Miranda de Ebro
IR Ayto. de Huelva
IR Ayto. de Errentería
ELRUIDO.COM
News and Events
Noticias

23-June-2005
Experts propose social working instead of fines as a penalty for these who drink alcohol outside on the street.

23-June-2005
BENALMÁDENA: Izquierda Unida denounces noise pollution caused by Palmasol hotel.

MORE

Environmental Quality

NOISE POLLUTION
Noise pollution is nowadays considered to be one of the biggest environmental problems, for it not only deteriorates the environment but it also causes physical and psychological disturbances to people who are exposed to certain noise levels.

MORE

SDR-100

Sound level recorder

An SDR-100 device image

ECUDAP SDR-100

Control SDR-100

  • Sound level recorder for noise control.

  • Record sonographic parameters LAeq60".

  • Record all incidents: disconnection ofelectrical network, handling.

  • Adjustable to any type of norm

  • Internal system of calibration.

  • Storage of data.

  • Configuration and obtaining of data thanksto our software.

 

Characteristics of an SDR-100


 INPUTS / OUTPUTS

5 Inputs of sensors for relays (0-5V) TTL

Technology

Output for connexion RS-232

Centronics 14

Capacity to send SMS (GSM).

Adapted to Monitoring systems of PdAudio

SSMmR

 MICROPHONE SENSOR

Microphonic capsule of condenser with the

characteristics of the type 2.

Measurement range

50 - 110 dBA

Frequencies range

20 - 20KHz

 CALIBRATION

Auto-calibration for each session

 DIMENSIONS AND WEIGHT

250 x 85 x 55 mm.

0,5 Kg.

  ALIMENTATION

220V 50 - 60 Hz

 MAXIMUM CONSUPTION

25 W

 STORAGE CAPACITY

Takes the data in a continuous way in Leq,as from one minute.

Further its configuration:

Sonographe: 255 sessions

Recorder: 4000 recordings

Functions of an SDR-100 device

     The sound level recorder SDR-100 records the noise levels in the premise it is installed.

    One of the objectives of the sound level recorder is to determine the periods of activity of the source of noise, thanks to the system of sensors. Another characteristic of the device is its inviolability. We lay out a monitoring system thanks to the sensor (microphone) which makes possible to detect possible handling. Inside the sensor, you have the Speaker/Amplifier/Converter D/A chain which has to detect the no-handling of these elements.

     Thus, a noise test (pink noise) is emitted. The both sensitivity/effectiveness of the period must remain constant throughout the sessions.

    The device can be programmed as a sonographe or as a recorder. As a sonographe, it records the following data:

Period of activity of the sources:

Expressed in sessions, determined by the period of time spent between the beginning and the ending work of the device. When the time spent between these two points is higher than 24 hours, the end of this session takes place automatically at the same hour then it began. The SDR-100 device is able to manage the noise of 4 different sound sources.

Period of a noisy activity:

The device gives us the time and date of the beginning of the activity in the premise, as from the moment when this level exceeds the fixed threshold. It also indicates when the noise level in the room goes down the fixed minimum threshold. From this period, the device preserves the levels of acoustic pressure generated in the room, expressed in:

- Time and date of the beginning of session.

- Time and date of the end of session.

- Efficacy of the both "Amplifier - Speaker – Microphone", in dB(A).

- Maximum signal level (Peak) which crosses the system.

- Medium equivalent level one minute of each session with its respective times and dates.

- Maximum equivalent level one minute.

- Minimum equivalent level one minute.

     As a recorder, the device takes continuously a sample of Leq 60", in a periodic way. This period has to be determined during the SDR-100 device programming.

Thus, the inspection will give us the 3000 latest recorded samples, divided in sessions determined by the activity of the source.

     The installation and modification of the parameters are made with our own software: GestionSDR. It is protected with various electronic keys:

- Program password

- Apparatus password

- Print of the program

     For a commodity inspection, you can read the data thanks to a laptop. This one can read and transfer them to a PC. This last one thanks to the Inspection program (our software GestionSDR), treats the data and works out an activity report of the device. The recorded data can be obtained by SMS transmission.

 